By Brands
Brands
Sub Categories
Analysis for 3P4W, 3P3W, 1P2W, 1P3W True RMS Value (V 123 and L 123 ) Active Power (W, KW, MW, GW) Apparent and Reactive Power (KVA, KVAR) Power Factor (PF), Phase Angle (Φ) Energy (WH, KWH, KVARH, PFH) Current Measurement from 0.1mA to 3000A, Capable of Analyzing IT Standby Power Consumption to the Maximum Demand of a Factory Display of 35 Parameters in One Screen(3P4W) Programmable CT (1 to 600) and PT (1 to 3000) Ratios Display of Overlapped Voltage and Current Waveform 2.4M Memory with Programmable Interval (1 to 6000 seconds, 17000 Records for 3P4W System) Output of Waveform, Power Parameters and Harmonics at Command Large Dot Matrix LCD Display with Backlight Average Demand (AD in W, KW, MW) Maximum Demand (MD in W, KW, MW) with Programmable Period Harmonic Analysis to the 99th Order Display of 50 Harmonics in One Screen with Waveform Display of Waveform with Peak Values (1024 Samples/Period) Analysis of Total Harmonic Distortion (%THD-F) Graphic Phasor Diagram with 3 Phase System Parameters Capture 28 Transient Events (Time + Cycles) with Programmable Threshold(%) 3 Phase Voltage Unbalance Ratio (VUR) 3 Phase Voltage Unbalance Factor (d0%,...
MODEL PROVA 19, 21, 23 True RMS value (V and A) Leakage Current Measurement at 10 μ A Resolution Harmonic Analysis (V and A) to the 99 th Order Better Understanding of High Frequency Harmonic Analysis (up to 5/6 KHz) Non-interrupted Harmonic Analysis Analysis of Total Harmonic Distortion (THD-F) Analysis of Crest Factor (C.F.) Fast Peak Function (33 μ s and 39 μ s) Programmable CT Ratio (1 to 250) Model 21(50A) and 23(100A) W, KW, H.P. VA, KVA, VAR, KVAR PF, Phase Angle ( Φ ) Energy (mWH, WH, KWH) Analysis of Standby Power Consumption Balanced 3 Φ Power Quality Balanced 3 Φ Sequence
Analysis for Single Phase and Balanced 3 phase system True RMS Value (V and I) Active Power (K,KW,MW,GW) Apparent (VA,KVA,MVA) and Reactive Power (VAR,KVAR,MVAR) Power Factor (PF), Phase Angle( Φ ) Energy (WH,KWH,KVARH,PFH) Programmable PT(1 to 3000)Ratios Display of Overlapped Voltage and Current Waveform Maximum Demand (MD in W,KW,MW) with programmable Period Harmonic Analysis (V and I) to 50th Order Display of 25 Harmonics in one screen Optical Isolated RS-232C Interface Smart Datalogging to save Battery Datalogging of 32,64,128 or 256 points/cycles Analysis of Total Harmonic Distortion (%THD-F) Graphic Phasor Diagram Capture 128 Transient Events (Time+Cycles+Faults) with Programmable Threshold(%),also can be reviewed in LCD 50000 Records with Programmable Interval (1 to 6000 seconds) Real-time Output of Waveform, Power Parameters and Harmonics at Command Large Dot Matrix LCD Display with Backlight Power for Long-term Monitoring Built -in Calendar Clock for Data Logging
True RMS 3000A Voltage Measurement (AFLEX 3002 only) Fast Peak Function(30 μs) MAX/MIN Auto-Power-Off:30 minutes Flexible probe, different from normal clamp meter, can pass through obstacles at will and wind many conducting wires simultaneously, max. diameter 170mm
Power Analysis (3005) W, KW, H.P. VA ,KVA, VAR, KVAR PF, Phase Angle( Φ ) Energy (WH, KWH) Dual displays (W+PF, VA+KVAR) Balanced 3 Φ Power Quality and Sequence Harmonics Analysis True RMS (V and A) 3000 A Non-interrupted Harmonic Analysis ( V and A ) to the 50th Order in % and Magnitude Analysis of % THD-F and C.F. Fast Peak Function (33μs and 39μs) Programmable PT (1 to 250 )ratios Auto - Power - Off : 30 Minutes
Display of Overlapped Voltage and Current Waveform Maximum Demand (MD in W, KW, MW) with Programmable Period Harmonics Analysis ( V and I ) to the 50th Order Display of 25 Harmonics in One Screen with Waveform Display of waveform with Peak Values (512 Samples / Period), Datalogging of 32, 64, 128 or 256 Points/Cycles Analysis of Total Harmonics Distortion ( % THD-F ) Graphic Phasor Diagram Programmable PT (1 to 3000) Ratios Capture 128 Transient Events ( Time + Cycles + Faults ) with Programmable Threshold(%), Can Also be Reviewed in LCD 50000 Records with Programmable Interval ( 1 to 6000 seconds) Output of Waveform, Power Parameters and 50 Harmonics at Command. Large Dot Matrix LCD Display with Backlight Optical Isolated RS-232C Interface Smart Datalogging to save Battery Power for Long-term Monitoring Built - in Calendar Clock for Data Logging
Portable Field Printing for Certificate Text and Graphics Two Selectable Fonts (5*7 and 8*16) Programmable text Header and Footer Battery and AC Power Adaptor RS-232C Interface (Optional RS-232C to USB Bridge) Fixed Interval Continuous Printing(5, 30, 60, 300 seconds)
4 digit LCD reading. Wide spectral range. Excellent long term stability. Cosine corrected. Automatic transmission measurements. Select either power or transmission. Solar energy measurement. Current time setting function. User calibration factor setting function. End-mount light sensor. Select either W/m2 or Btu / (ft2 x h) units. Data hold/MAX/MIN/AVG modes. Auto Data Memory function. (microSD CARD 2GB) Manual Data Memory and Read function. (99 sets) Auto power off function. USB interface.